CIM-50-Ethernet Module with GPS

Features

• For permanent installation onto a rectifier exterior
– new or retrofit
– indoor or outdoor
• GPS synchronized, always on
• Remotely activated via Ethernet connection or 24V pulse
• Powered by local AC
• Capable of interrupting up to 50A either DC or AC
• 5 programmable interruption cycles
• Comprehensive 1 year warranty

Add to Quote

Description

Spec Sheet  CIM-50 Ethernet Manual 

Technical Specification

• Power requirement: 100-250VAC 50/60Hz 0.5A
• Capacity: Up to 50A at 125VDC or 50A at 250VAC
• Switching: Internal mechanical relay (can be mounted in rectifier cabinet if necessary)
• Case: IP66 / NEMA 4X fiberglass case with locking clasp and external feet
• Dimensions: 30cm x 25cm x 18cm (12” x 10” x 7”)
• Weight: 5 kg (11 lb)
• Two standard methods of communication;
– Ethernet based Modbus TCP protocol with built in web server interface
– 24 V DC pulse based signaling
– Flexible design, other signaling schemes available, please contact factory
• GPS synchronized, with internal GPS (can be mounted externally if necessary)
– Cycle time 1/4 sec to 6 min
– Off time: 0 to 9999mSec (synchronized to the beginning of the minute, 0 seconds)
• Non GPS synchronized operation also possible
• Configuration via keypad 

Translate »